Poly-Girder™ - Strengthen & Protect Bridge Infrastructures

Poly-Girder™ - Strengthen and Protect Bridge Infrastructures

Low Cost - No Maintenance - High Value

Structural Challenges & the Need for Innovation


Natural disasters, human-caused events, material degradation, and chemical attacks cause thousands of deaths and billions in structural damage annually. To address this, Power Polymer Solutions developed the C-IDA Poly-Girder system—a chemically engineered solution to reinforce and retrofit aging or damaged infrastructure.


PowerPolymer Solutions: Key Benefits

The Poly-Girder system can be applied to existing structures or used as a stand-alone energy-absorbing solution. It offers:


  • Easy application
  • Compatibility with any material or shape
  • High impact resistance and energy dissipation
  • Exceptional fracture toughness
  • Ideal for both rehabilitation and new construction
  • Proven durability under extreme conditions
  • Self-healing properties with zero maintenance
  • Protection against surge and surface waves


Bridge Applications


  • Coastal & Seismic Zones
  • Poly-Girder is specifically designed to reinforce girder-to-cap connections in:
  • Coastal bridges exposed to hurricanes
  • Bridges and buildings in high seismic regions
  • Performance Enhancements
  • Increases ductility by 50%
  • Boosts strength by 100%


Retrofitting Concrete-Encased Steel Girders


  • Post-Failure Recovery
  • Retrofitted girders subjected to four-point bending after catastrophic failure retained over 68% of their peak strength. Damage included:
  • Crushing of mid-span compression zones
  • Fracturing of 50% of the steel web depth
  • These girders were repaired using PowerPolymer technology.


Comparative Testing


  • PowerPolymer retrofitted girders absorbed shock energy and halted crack propagation.
  • CFRP retrofitted girders failed immediately upon reaching peak strength.
  • PowerPolymer retrofitted girders achieved 3× the displacement of CFRP counterparts.
  • No de-bonding observed during maximum deflection tests.


Hurricane Katrina Case Study

Without Poly-Girder Protection:

  • The I-10 Bayway bridge across Mobile Bay failed catastrophically at the girder-to-cap beam connection after less than one cycle of wave force during Hurricane Katrina.


With Poly-Girder Protection:

  • The same connection, retrofitted with Poly-Girder, withstood 12 cycles of Katrina-level dynamic forces—remaining fully operational and serviceable.


Poly-Girder Testing Library

Includes visual documentation of:


  • Severe seismic damage to concrete-encased steel specimens
  • Maximum deflection of C-IDA-retrofitted girders
  • Load vs. mid-span deflection comparisons between C-IDA and CFRP systems
Contact PowerPolymer
August 30, 2025
Protect lives, homes, and communities from nature’s most destructive forces.
solder
August 25, 2025
Decrease fatalities among troops, law enforcement officers, and first responders with Poly-Defender shatter proof, blast resistant ruck sacks, vests, helmets, and body armor.